Advertisement

Bci Joist Hole Chart

Bci Joist Hole Chart - 1 out of 2 found this helpful. Web floor note (zee page 5, 6, 9) 7100r loads are 40 psf li'.e load and 10 psf dead load. • floor tile will increase dead load and may require specific deflection limits, contact boise cascade ewp engineering for further information. Web spans based on l/480 deflection and desgin loads of 40 psf live and 10 psf dead. Deflection is limited to 1_/360 live load and 1_/240 total load. • bci® joist to support: Web it can be as simple as needing additional space to accommodate large hvac or plumbing systems. Web since the introduction of smoke detectors into homes, fire deaths have been reduced by nearly 50 percent. Tables assume a wall weight of 100 plf (pages 6, 9). Web storage and installation:

Deflection is limited to 1_/360 live load and 1_/240 total load. Bc calc ® analysis often allows for larger holes or placement closer to bearing supports when compared to tables in our printed literature. • floor tile will increase dead load and may require specific deflection limits, contact boise cascade ewp engineering for further information. • this table was designed to apply to a broad range of applications. Web it can analyze specific hole sizes and locations for the actual joist loading and span condition. Bci® joists are used as floor joists and roof rafters. Boise cascade product specifier guides, installation guides, and product guides; Web since the introduction of smoke detectors into homes, fire deaths have been reduced by nearly 50 percent. Allowable shear values with web holes (v hole) can be calculated based on the tabulated allowable shear values (v r), hole size, and hole type using the following equations: Web tables are based on uniform load tables in current design literature.

BCI® Joists Resources Boise Cascade
Bci Floor Joist Span Chart Floor Roma
Bci Joist Hole Chart
Bci Joist Hole Chart
Bci Joist Hole Chart
Bci Joist Hole Chart
Bci Joist Hole Chart
Bci Floor Joist Span Chart Floor Roma
Span and Size Charts for BCI Joists Boise Cascade
bci joists span tables

Web Bci® Joist Hole Location.

For simple span (5' minimum), uniformly loaded joists used in residential applications, one maximum size round hole may be located at the center of the joist span provided that no other holes occur in the joist. Web span and size charts for engineered wood products. • bci® joist to support: They shall be handled with care so they are not damaged.

Web Storage And Installation:

Web since the introduction of smoke detectors into homes, fire deaths have been reduced by nearly 50 percent. Boise cascade product specifier guides, installation guides, and product guides; Table based upon either simple or continuous floor joist spans. Or it can be technical, such as the need to support heavier loads or longer spans.

Web The Specific Gravity For The Bci Flanges Shall Be Limited To 0.43 For Edge Nail Withdrawal, And 0.50 For Face Nail Withdrawal, Nail Lateral, And Bolt Lateral.

Technical notes for bci joists 1 out of 2 found this helpful. Do cut in web area as specified. Web it can be as simple as needing additional space to accommodate large hvac or plumbing systems.

Allowable Shear Values With Web Holes (V Hole) Can Be Calculated Based On The Tabulated Allowable Shear Values (V R), Hole Size, And Hole Type Using The Following Equations:

The bci joists, if stored prior to erection, shall be stored in a vertical and level position and protected from the weather. Web engineered wood products (ewp) span and size charts for bci ® joists. Deflection is limited to 1_/360 live load and 1_/240 total load. Web • table values assume minimum bearing lengths without web stiffeners for joist depths of 16 inches and less.